Utility-interactive Mode
|
Battery charge/discharge voltage
|
250~520V(rated 450V)
|
PV charge/discharge voltage
|
520~900V
|
Maximum PV current
|
400A
|
AC voltage
|
400V±10%
|
Nominal power
|
100KW
|
AC frequency
|
50Hz/60Hz
|
AC PF
|
Listed: 0.8~1 leading or lagging(Controllable)
Actual capability: 0.1~1 leading or lagging(Controllable)
|
Stand-alone Mode
|
Battery charge/discharge voltage
|
250~520V
|
PV charge/discharge voltage
|
520~900V
|
Maximum PV power |
200KW
|
AC output voltage
|
400V(±5% configurable)
|
Nominal AC output power
|
100kW
|
AC frequency
|
50Hz/60Hz
|
AC output PF
|
Listed: 0.8~1 leading or lagging (Load-depend)
Actual capability: 0.1~1 leading or lagging(Load-depend)
|
Overload Capability
|
105%~115% 10min;
115%~125% 1min;
125%~150% 200ms
|
Physical
|
Cooling
|
Forced air cooling with replaceable fan module
|
Noise
|
<75dB
|
Enclosure
|
IP20/NEMA1
|
Max elevation
|
3000m/10000feet (> 2000m/6500feet derating)
|
Operating temp.
|
-20°C to 60°C (De-rating over 45°C)
|
Humidity
|
0~95% (No condensing)
|
Size (W*H*D)
|
800*2160*800mm/
31.5*85.04*31.5 inches
|
Weight
|
750kgs
|
Installation
|
Floor standing
|
Other
|
Peak efficiency
|
95.5%
|
Protection
|
OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding
|
Configurable protection limits
|
Upper/Lower AC Voltage/Frequency limit, Battery
EOD voltage.
|
AC connection
|
3-Phase 4-Wire
|
Communication
|
Ethernetport
|
x1RJ45 slot, for EMS, via MODBUS TCP/IP
|
RS-485 port
|
x1RJ45 slot, for EMS or BMS, EMS via MODBUS RTU.
two kinds of BMS communication protocol supported
|